10 research outputs found

    A Learning-based Method for Online Adjustment of C-arm Cone-Beam CT Source Trajectories for Artifact Avoidance

    Full text link
    During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides intraoperative 3D tomographic imaging which would allow for immediate verification and, if needed, revision. However, the reconstruction quality attainable with commercial CBCT devices is insufficient, predominantly due to severe metal artifacts in the presence of pedicle screws. These artifacts arise from a mismatch between the true physics of image formation and an idealized model thereof assumed during reconstruction. Prospectively acquiring views onto anatomy that are least affected by this mismatch can, therefore, improve reconstruction quality. We propose to adjust the C-arm CBCT source trajectory during the scan to optimize reconstruction quality with respect to a certain task, i.e. verification of screw placement. Adjustments are performed on-the-fly using a convolutional neural network that regresses a quality index for possible next views given the current x-ray image. Adjusting the CBCT trajectory to acquire the recommended views results in non-circular source orbits that avoid poor images, and thus, data inconsistencies. We demonstrate that convolutional neural networks trained on realistically simulated data are capable of predicting quality metrics that enable scene-specific adjustments of the CBCT source trajectory. Using both realistically simulated data and real CBCT acquisitions of a semi-anthropomorphic phantom, we show that tomographic reconstructions of the resulting scene-specific CBCT acquisitions exhibit improved image quality particularly in terms of metal artifacts. Since the optimization objective is implicitly encoded in a neural network, the proposed approach overcomes the need for 3D information at run-time.Comment: 12 page

    Trainable Joint Bilateral Filters for Enhanced Prediction Stability in Low-dose CT

    Full text link
    Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning~(DL)-based methods were introduced, outperforming conventional denoising algorithms on this task due to their high model capacity. However, for the transition of DL-based denoising to clinical practice, these data-driven approaches must generalize robustly beyond the seen training data. We, therefore, propose a hybrid denoising approach consisting of a set of trainable joint bilateral filters (JBFs) combined with a convolutional DL-based denoising network to predict the guidance image. Our proposed denoising pipeline combines the high model capacity enabled by DL-based feature extraction with the reliability of the conventional JBF. The pipeline's ability to generalize is demonstrated by training on abdomen CT scans without metal implants and testing on abdomen scans with metal implants as well as on head CT data. When embedding two well-established DL-based denoisers (RED-CNN/QAE) in our pipeline, the denoising performance is improved by 10%10\,\%/82%82\,\% (RMSE) and 3%3\,\%/81%81\,\% (PSNR) in regions containing metal and by 6%6\,\%/78%78\,\% (RMSE) and 2%2\,\%/4%4\,\% (PSNR) on head CT data, compared to the respective vanilla model. Concluding, the proposed trainable JBFs limit the error bound of deep neural networks to facilitate the applicability of DL-based denoisers in low-dose CT pipelines

    Calibration by differentiation – Self‐supervised calibration for X‐ray microscopy using a differentiable cone‐beam reconstruction operator

    Get PDF
    High‐resolution X‐ray microscopy (XRM) is gaining interest for biological investigations of extremely small‐scale structures. XRM imaging of bones in living mice could provide new insights into the emergence and treatment of osteoporosis by observing osteocyte lacunae, which are holes in the bone of few micrometres in size. Imaging living animals at that resolution, however, is extremely challenging and requires very sophisticated data processing converting the raw XRM detector output into reconstructed images. This paper presents an open‐source, differentiable reconstruction pipeline for XRM data which analytically computes the final image from the raw measurements. In contrast to most proprietary reconstruction software, it offers the user full control over each processing step and, additionally, makes the entire pipeline deep learning compatible by ensuring differentiability. This allows fitting trainable modules both before and after the actual reconstruction step in a purely data‐driven way using the gradient‐based optimizers of common deep learning frameworks. The value of such differentiability is demonstrated by calibrating the parameters of a simple cupping correction module operating on the raw projection images using only a self‐supervisory quality metric based on the reconstructed volume and no further calibration measurements. The retrospective calibration directly improves image quality as it avoids cupping artefacts and decreases the difference in grey values between outer and inner bone by 68–94%. Furthermore, it makes the reconstruction process entirely independent of the XRM manufacturer and paves the way to explore modern deep learning reconstruction methods for arbitrary XRM and, potentially, other flat‐panel computed tomography systems. This exemplifies how differentiable reconstruction can be leveraged in the context of XRM and, hence, is an important step towards the goal of reducing the resolution limit of in vivo bone imaging to the single micrometre domain

    Ultralow‐parameter denoising: trainable bilateral filter layers in computed tomography

    Get PDF
    Background Computed tomography (CT) is widely used as an imaging tool to visualize three-dimensional structures with expressive bone-soft tissue contrast. However, CT resolution can be severely degraded through low-dose acquisitions, highlighting the importance of effective denoising algorithms. Purpose Most data-driven denoising techniques are based on deep neural networks, and therefore, contain hundreds of thousands of trainable parameters, making them incomprehensible and prone to prediction failures. Developing understandable and robust denoising algorithms achieving state-of-the-art performance helps to minimize radiation dose while maintaining data integrity. Methods This work presents an open-source CT denoising framework based on the idea of bilateral filtering. We propose a bilateral filter that can be incorporated into any deep learning pipeline and optimized in a purely data-driven way by calculating the gradient flow toward its hyperparameters and its input. Denoising in pure image-to-image pipelines and across different domains such as raw detector data and reconstructed volume, using a differentiable backprojection layer, is demonstrated. In contrast to other models, our bilateral filter layer consists of only four trainable parameters and constrains the applied operation to follow the traditional bilateral filter algorithm by design. Results Although only using three spatial parameters and one intensity range parameter per filter layer, the proposed denoising pipelines can compete with deep state-of-the-art denoising architectures with several hundred thousand parameters. Competitive denoising performance is achieved on x-ray microscope bone data and the 2016 Low Dose CT Grand Challenge data set. We report structural similarity index measures of 0.7094 and 0.9674 and peak signal-to-noise ratio values of 33.17 and 43.07 on the respective data sets. Conclusions Due to the extremely low number of trainable parameters with well-defined effect, prediction reliance and data integrity is guaranteed at any time in the proposed pipelines, in contrast to most other deep learning-based denoising architectures

    On the Benefit of Dual-domain Denoising in a Self-supervised Low-dose CT Setting

    Full text link
    Computed tomography (CT) is routinely used for three-dimensional non-invasive imaging. Numerous data-driven image denoising algorithms were proposed to restore image quality in low-dose acquisitions. However, considerably less research investigates methods already intervening in the raw detector data due to limited access to suitable projection data or correct reconstruction algorithms. In this work, we present an end-to-end trainable CT reconstruction pipeline that contains denoising operators in both the projection and the image domain and that are optimized simultaneously without requiring ground-truth high-dose CT data. Our experiments demonstrate that including an additional projection denoising operator improved the overall denoising performance by 82.4-94.1%/12.5-41.7% (PSNR/SSIM) on abdomen CT and 1.5-2.9%/0.4-0.5% (PSNR/SSIM) on XRM data relative to the low-dose baseline. We make our entire helical CT reconstruction framework publicly available that contains a raw projection rebinning step to render helical projection data suitable for differentiable fan-beam reconstruction operators and end-to-end learning.Comment: This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessibl

    Noise2Contrast: Multi-Contrast Fusion Enables Self-Supervised Tomographic Image Denoising

    Full text link
    Self-supervised image denoising techniques emerged as convenient methods that allow training denoising models without requiring ground-truth noise-free data. Existing methods usually optimize loss metrics that are calculated from multiple noisy realizations of similar images, e.g., from neighboring tomographic slices. However, those approaches fail to utilize the multiple contrasts that are routinely acquired in medical imaging modalities like MRI or dual-energy CT. In this work, we propose the new self-supervised training scheme Noise2Contrast that combines information from multiple measured image contrasts to train a denoising model. We stack denoising with domain-transfer operators to utilize the independent noise realizations of different image contrasts to derive a self-supervised loss. The trained denoising operator achieves convincing quantitative and qualitative results, outperforming state-of-the-art self-supervised methods by 4.7-11.0%/4.8-7.3% (PSNR/SSIM) on brain MRI data and by 43.6-50.5%/57.1-77.1% (PSNR/SSIM) on dual-energy CT X-ray microscopy data with respect to the noisy baseline. Our experiments on different real measured data sets indicate that Noise2Contrast training generalizes to other multi-contrast imaging modalities

    Deep learning for terahertz image denoising in nondestructive historical document analysis

    No full text
    Abstract Historical documents contain essential information about the past, including places, people, or events. Many of these valuable cultural artifacts cannot be further examined due to aging or external influences, as they are too fragile to be opened or turned over, so their rich contents remain hidden. Terahertz (THz) imaging is a nondestructive 3D imaging technique that can be used to reveal the hidden contents without damaging the documents. As noise or imaging artifacts are predominantly present in reconstructed images processed by standard THz reconstruction algorithms, this work intends to improve THz image quality with deep learning. To overcome the data scarcity problem in training a supervised deep learning model, an unsupervised deep learning network (CycleGAN) is first applied to generate paired noisy THz images from clean images (clean images are generated by a handwriting generator). With such synthetic noisy-to-clean paired images, a supervised deep learning model using Pix2pixGAN is trained, which is effective to enhance real noisy THz images. After Pix2pixGAN denoising, 99% characters written on one-side of the Xuan paper can be clearly recognized, while 61% characters written on one-side of the standard paper are sufficiently recognized. The average perceptual indices of Pix2pixGAN processed images are 16.83, which is very close to the average perceptual index 16.19 of clean handwriting images. Our work has important value for THz-imaging-based nondestructive historical document analysis

    DeepNAPSI multi-reader nail psoriasis prediction using deep learning

    No full text
    Abstract Nail psoriasis occurs in about every second psoriasis patient. Both, finger and toe nails can be affected and also severely destroyed. Furthermore, nail psoriasis is associated with a more severe course of the disease and the development of psoriatic arthritis. User independent quantification of nail psoriasis, however, is challenging due to the heterogeneous involvement of matrix and nail bed. For this purpose, the nail psoriasis severity index (NAPSI) has been developed. Experts grade pathological changes of each nail of the patient leading to a maximum score of 80 for all nails of the hands. Application in clinical practice, however, is not feasible due to the time-intensive manual grading process especially if more nails are involved. In this work we aimed to automatically quantify the modified NAPSI (mNAPSI) of patients using neuronal networks retrospectively. First, we performed photographs of the hands of patients with psoriasis, psoriatic arthritis, and rheumatoid arthritis. In a second step, we collected and annotated the mNAPSI scores of 1154 nail photos. Followingly, we extracted each nail automatically using an automatic key-point-detection system. The agreement among the three readers with a Cronbach’s alpha of 94% was very high. With the nail images individually available, we trained a transformer-based neural network (BEiT) to predict the mNAPSI score. The network reached a good performance with an area-under-receiver-operator-curve of 88% and an area-under precision-recall-curve (PR-AUC) of 63%. We could compare the results with the human annotations and achieved a very high positive Pearson correlation of 90% by aggregating the predictions of the network on the test set to the patient-level. Lastly, we provided open access to the whole system enabling the use of the mNAPSI in clinical practice